Part Number Hot Search : 
SG2540DW BX6153 1GTR2 AMN12111 SG2540DW AD5415 PE44205 C68HC05
Product Description
Full Text Search
 

To Download DS75LX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 DS75LX
Digital Thermometer and Thermostat with Extended Addressing www.maxim-ic.com
GENERAL DESCRIPTION
This low-voltage (1.7V to 3.7V) digital thermometer and thermostat provides 9, 10, 11, or 12-bit digital temperature readings over a -55C to +125C range with 2C accuracy over a -25C to +100C range. At power-up, the DS75LX defaults to 9-bit resolution for software compatibility with the LM75. Communication with the DS75LX is achieved through a simple 2-wire serial interface. Three tri-state address pins allow up to 27 DS75LX devices to operate on the same 2-wire bus, which greatly simplifies distributed temperaturesensing applications. The DS75LX thermostat has a dedicated open-drain output (O.S.) and programmable fault tolerance, which allow the user to define the number of consecutive error conditions that must occur before O.S. is activated. There are two thermostatic operating modes that control thermostat operation based on user-defined trip-points (TOS and THYST).
FEATURES
1.7V to 3.7V Operating Range Tri-State Address Pins Allow Up to 27 Unique Bus Addresses Temperature Measurements Require No External Components Measures Temperatures from -55C to +125C (-67F to +257F) 2C Accuracy from -25C to +100C Thermometer Resolution Is UserConfigurable from 9 (Default) to 12 Bits (0.5C to 0.0625C Resolution) 9-Bit Conversion Time is 25ms (max) Thermostatic Settings are User-Definable Data is Read/Written Through 2-Wire Serial Interface (SDA and SCL Pins) Data Lines Filtered Internally for Noise Immunity (50ns Deglitch) Bus Timeout Feature Prevents Lockup Problems on 2-Wire Interface Multidrop Capability Simplifies Distributed Temperature-Sensing Applications Pin/Software Compatible with the LM75 Available in 8-Pin SOP (MAX(R)) and SO Packages
APPLICATIONS
Any Thermally Sensitive System Cellular Base Stations Telecom Switches and Routers Servers
PIN CONFIGURATIONS
SDA SCL O.S. GND
1 8
ORDERING INFORMATION
PART TEMP RANGE -55C to +125C -55C to +125C -55C to +125C -55C to +125C
VDD A0
DS75LXS+ DS75LXS+T&R
2 3 4
7 6 5
A1 A2
DS75LXU+ DS75LXU+T&R
SO (150 mils) SDA SCL O.S. GND
1 8
PIN PACKAGE 8 SO (150 mils) 8 SO (150 mils), 2500 Piece 8 SOP (MAX) 8 SOP (MAX), 3000 Piece
DS75 LX DS75 LX
VDD A0 A1 A2
+ Denotes lead-free package. T&R denotes tape-and-reel. Note: A "+" symbol will also be marked on the package near the pin 1 indicator. MAX is a registered trademark of Maxim Integrated Products, Inc.
2 3 4
7 6 5
SOP/MAX
1 of 13
050307
DS1386/DS1386P
ABSOLUTE MAXIMUM RATINGS
Voltage Range on VDD, Relative to Ground Voltage Range on Any Other Pin, Relative to Ground Operating Temperature Range Storage Temperature Range Soldering Temperature -0.3V to +4.0V -0.3V to +6.0V -55C to +125C -55C to +125C See IPC/JEDEC J-STD-020
These are stress ratings only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.
The Dallas Semiconductor DS75LX is built to the highest quality standards and manufactured for long-term reliability. All Dallas Semiconductor devices are made using the same quality materials and manufacturing methods. However, the DS75LX is not exposed to environmental stresses, such as burn-in, that some industrial applications require. For specific reliability information on this product, contact the factory in Dallas at (972) 3714448.
DC ELECTRICAL CHARACTERISTICS
(1.7V VDD 3.7V, TA = -55C to +125C.) PARAMETER SYMBOL Supply Voltage VDD Thermometer Error TERR (Note 2) Input Logic-High SDA, VIH SCL Input Logic-Low SDA, VIL SCL VOL1 SDA Output Logic-Low Voltage (Note 3) VOL2 O.S. Saturation Voltage Input Current SDA, SCL I/O Capacitance Address Input Sink Current Address Input Source Current Address Voltage High Address Voltage Low Standby Current Active Current (Notes 1, 4, 5) VOL CI/O ILAH ILAL VAH VAL IDD1 IDD A0, A1, or A2 tied to VDD (Notes 4, 5) A0, A1, or A2 tied to GND (Notes 4, 5) (Note 6) (Note 6) (Notes 4, 5) Active temp conversions Communication only 0.2 0.2 VDD - .04 VSS + .04 13 1000 100 CONDITIONS (Note 1) -25C to +100C -55C to +125C (Note 3) MIN 1.7 MAX 3.7 2.0 3.0 VDD + 0.3 0.3 x VDD 0.4 0.6 0.8 -10 +10 10 3.5 3.5 UNITS V C V V V V A pF A A V V A A
0.7 x VDD VSS - 0.3
3mA sink current 6mA sink current 4mA sink current (Notes 2, 3) 0.4 < VI/O < 0.9VDD
0 0
AC ELECTRICAL CHARACTERISTICS
(1.7V VDD 3.7V, TA = -55C to +125C.) PARAMETER SYMBOL Resolution CONDITIONS MIN 9 TYP MAX 12 25 50 ms 11-bit conversions 12-bit conversions 100 200 UNITS Bits
9-bit conversions Temperature Conversion Time 10-bit conversions tCONVT
2 of 13
SCL Frequency
fSCL
DS75LX: Digital Thermometer and Thermostat with Extended Addressing 400 kHz
AC ELECTRICAL CHARACTERISTICS (continued)
(1.7V VDD 3.7V, TA = -55C to +125C.) PARAMETER SYMBOL Bus Free Time Between tBUF a STOP and START Condition START and Repeated tHD:STA START Hold Time from Falling SCL Low Period of SCL tLOW High Period of SCL tHIGH Repeated START tSU:STA Condition Setup Time to Rising SCL Data-Out Hold Time from tHD:DAT Falling SCL Data-In Setup Time to tSU:DAT Rising SCL Rise Time of SDA and tR SCL (Receive) Fall Time of SDA and tF SCL (Receive) Spike Suppression tSS Filter Time (Deglitch Filter) STOP Setup Time to tSU:STO Rising SCL Capacitive Load for Each CB Bus Line Input Capacitance CI Serial Interface Reset tTIMEOUT Time
B
CONDITIONS (Note 7)
MIN 1.3
TYP
MAX
UNITS s
(Notes 7, 8) (Note 7) (Note 7) (Note 7) (Notes 7, 9) (Note 7) (Notes 7, 10) (Notes 7, 10)
600 1.3 0.6 600 0 100 20 + 0.1CB 20 + 0.1CB
B B
ns s s ns 0.9 s ns 300 300 50 ns ns ns ns 400 5 pF pF 325 ms
0 (Note 7) 600
SDA time low (Notes 11, 12)
75
Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Note 10: Note 11: Note 12:
VDD must be decoupled with a high-quality 0.1F bypass capacitor. X5R or X7R ceramic surface-mount capacitors are recommended. Internal heating caused by O.S. loading causes the DS75LX to read approximately 0.5C higher if O.S. is sinking the max rated current. All voltages are referenced to ground. IDD specified with O.S. pin open and A0-A2 pins grounded. IDD and address leakage specified with VDD at 3.0V and SDA, SCL = 3.0V at 0C to +70C. Address pins A0, A1, A2 are directly connected to VDD, VSS, or floating with less than 50pF capacitive load. See the timing diagram (Figure 1). All timing is referenced to 0.9 x VDD and 0.1 x VDD. After this period, the first clock pulse is generated. The DS75LX provides an internal hold time of at least 75ns on the SDA signal to bridge the undefined region of SCL's falling edge. For example, if CB = 300pF, then tR[min] = tF[min] = 50ns. This timeout applies only when the DS75LX is holding SDA low. Other devices can hold SDA low indefinitely and the DS75LX will not reset. The DS75LX is available with timeout feature disabled upon special order. Contact Factory.
PIN DESCRIPTION
PIN 1 2 3 4 5 6 7 8 NAME SDA SCL O.S. GND A2 A1 A0 VDD FUNCTION Data Input/Output for 2-Wire Serial Communication Port (Open Drain) Clock Input for 2-Wire Serial Communication Port Thermostat Output Open Drain Ground Address Input Address Input Address Input Supply Voltage. +1.7V to +3.7V supply pin. VDD must have an external bypass capacitor to GND. 0.1F X5R or X7R ceramic SMT caps recommended. 3 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
BLOCK DIAGRAM
PRECISION REFERENCE
OVERSAMPLING MODULATOR
DIGITAL DECIMATOR
VDD CONFIGURATION REGISTER ADDRESS AND I/O CONTROL
SCL SDA A0 A1 A2
TEMPERATURE REGISTER O.S. TOS AND THYST REGISTERS THERMOSTAT COMPARATOR
RP
GND
Figure 1. Timing Diagram
4 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
OPERATION--MEASURING TEMPERATURE
The DS75LX measures temperature using a bandgap temperature-sensing architecture. An on-board delta-sigma analog-to-digital converter (ADC) converts the measured temperature to a digital value that is calibrated in degrees celsius; for Fahrenheit applications a lookup table or conversion routine must be used. The DS75LX is factorycalibrated and requires no external components to measure temperature. At power-up the DS75LX immediately begins measuring and converting its own temperature to a digital value. The resolution of the digital output data is user-configurable to 9, 10, 11, or 12 bits, corresponding to temperature increments of 0.5C, 0.25C, 0.125C, and 0.0625C, respectively, with 9-bit default resolution at power-up. The resolution is controlled via the R0 and R1 bits in the configuration register as explained in the Configuration Register section of this data sheet. Note that the conversion time doubles for each additional bit of resolution. After each temperature measurement and analog-to-digital conversion, the DS75LX stores the temperature as a 16-bit two's complement number in the 2-byte temperature register (see Figure 2). The sign bit (S) indicates if the temperature is positive or negative: for positive numbers S = 0 and for negative numbers S = 1. The most recently converted digital measurement can be read from the temperature register at any time. Since temperature conversions are performed in the background, reading the temperature register does not affect the operation in progress. Bits 3 through 0 of the temperature register are hardwired to 0. When the DS75LX is configured for 12-bit resolution, the 12 MSbs (bits 15 through 4) of the temperature register contain temperature data. For 11-bit resolution, the 11 MSbs (bits 15 through 5) of the temperature register contain data, and bit 4 reads out as 0. Likewise, for 10-bit resolution, the 10 MSbs (bits 15 through 6) contain data, and for 9-bit the 9 MSbs (bits 15 through 7) contain data, and all unused LSbs will contain 0s. Table 1 gives examples of 12-bit resolution digital output data and the corresponding temperatures.
Figure 2. Temperature, TH, and TL Register Format
MS Byte bit 15 S bit 7 2-1 bit 14 26 bit 6 2-2 bit 13 25 bit 5 2-3 bit 12 24 bit 4 2-4 bit 11 23 bit 3 0 bit 10 22 bit 2 0 bit 9 21 bit 1 0 bit 8 20 bit 0 0
LS Byte
Table 1. 12-Bit Resolution Temperature/Data Relationship
TEMPERATURE (C) +125 +25.0625 +10.125 +0.5 0 -0.5 -10.125 -25.0625 -55 DIGITAL OUTPUT (BINARY) 0111 1101 0000 0000 0001 1001 0001 0000 0000 1010 0010 0000 0000 0000 1000 0000 0000 0000 0000 0000 1111 1111 1000 0000 1111 0101 1110 0000 1110 0110 1111 0000 1100 1001 0000 0000 DIGITAL OUTPUT (HEX) 7D00h 1910h 0A20h 0080h 0000h FF80h F5E0h E6F0h C900h
5 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Shutdown Mode
For power-sensitive applications, the DS75LX offers a low-power shutdown mode. The SD bit in the configuration register controls shutdown mode. When SD is changed to 1, the conversion in progress is completed and the result is stored in the temperature register after which the DS75LX goes into a low-power standby state. The O.S. output is cleared if the thermostat is operating in interrupt mode, and O.S remains unchanged in comparator mode. The 2wire interface remains operational in shutdown mode, and writing a 0 to the SD bit returns the DS75LX to normal operation.
OPERATION--THERMOSTAT
The DS75LX thermostat has two operating modes, comparator mode and interrupt mode, which activate and deactivate the open-drain thermostat output (O.S.) based on user-programmable trip-points (TOS and THYST). The DS75LX powers up with the thermostat in comparator mode with active-low O.S. polarity and with the overtemperature trip-point (TOS) register set to +80C and the hysteresis trip-point (THYST) register set to +75C. If these power-up settings are compatible with the application, the DS75LX can be used as a stand-alone thermostat (i.e., no 2-wire communication required). If interrupt mode operation, active-high O.S. polarity, or different TOS and THYST values are desired, they must be programmed after power-up, so stand-alone operation is not possible. In both operating modes, the user can program the thermostat fault tolerance, which sets how many consecutive temperature readings (1, 2, 4, or 6) must fall outside of the thermostat limits before the thermostat output is triggered. The fault tolerance is set by the F1 and F0 bits in the configuration register and at power-up the fault tolerance is 1. The data format of the TOS and THYST registers is identical to that of the temperature register (see Figure 2), i.e., a 2-byte two's complement representation of the trip-point temperature in degrees celcius with bits 3 through 0 hardwired to 0. After every temperature conversion, the measured temperature is compared to the values in the TOS and THYST registers, and then O.S. is updated based on the result of the comparison and the operating mode. The number of TOS and THYST bits used during the thermostat comparison is equal to the conversion resolution set by the R1 and R0 bits in the configuration register. For example, if the resolution is 9 bits, only the 9 MSbs of TOS and THYST will be used by the thermostat comparator. The active state of the O.S. output can be changed by the POL bit in the configuration register. The power-up default is active low. If the user does not wish to use the thermostat capabilities of the DS75LX, the O.S. output should be left floating. Note that if the thermostat is not used, the TOS and THYST registers can be used for general storage of system data.
Comparator Mode
When the thermostat is in comparator mode, O.S. can be programmed to operate with any amount of hysteresis. The O.S. output becomes active when the measured temperature exceeds the TOS value a consecutive number of times as defined by the F1 and F0 fault tolerance (FT) bits in the configuration register. O.S. then stays active until the first time the temperature falls below the value stored in THYST. Putting the device into shutdown mode does not clear O.S. in comparator mode. Thermostat comparator mode operation with FT = 2 is illustrated in Figure 3.
Interrupt Mode
In interrupt mode, the O.S. output first becomes active when the measured temperature exceeds the TOS value a consecutive number of times equal to the FT value in the configuration register. Once activated, O.S. can only be cleared by either putting the DS75LX into shutdown mode or by reading from any register (temperature, configuration, TOS, or THYST ) on the device. Once O.S. has been deactivated, it will only be reactivated when the measured temperature falls below the THYST value a consecutive number of times equal to the FT value. Again, O.S can only be cleared by putting the device into shutdown mode or reading any register. Thus, this interrupt/clear process is cyclical between TOS and THYST events (i.e, TOS, clear, THYST, clear, TOS, clear, THYST, clear, etc.). Thermostat interrupt mode operation with FT = 2 is illustrated in Figure 3.
6 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Figure 3. O.S. Output Operation Example
In this example the DS75LX is configured to have a fault tolerance of 2. TOS Temperature THYST
Inactive
O.S. Output - Comparator Mode
Active
Inactive
O.S. Output - Interrupt Mode
Active
Assumes an interrupt clear event has occurred
Conversions
Configuration Register
The configuration register allows the user to program various DS75LX options such as conversion resolution, thermostat fault tolerance, thermostat polarity, thermostat operating mode, and shutdown mode. The configuration register is arranged as shown in Figure 4 and detailed descriptions of each bit are provided in Table 2. The user has read/write access to all bits in the configuration register except the MSb, which is a reserved read-only bit. The entire register is volatile, and thus powers up in its default state.
Figure 4. Configuration Register
MSb bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 LSb
0
R1
R0
F1
F0
POL
TM
SD
7 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Table 2. Configuration Register Bit Descriptions
BIT NAME 0 Reserved R1 Conversion Resolution Bit 1 R0 Conversion Resolution Bit 0 F1 Thermostat Fault Tolerance Bit 1 F0 Thermostat Fault Tolerance Bit 0 POL Thermostat Output (O.S.) Polarity DESCRIPTION Power-Up State = 0 The master can write to this bit, but it always reads out as a 0. Power-Up State = 0 Sets conversion resolution (see Table 3). Power-Up State = 0 Sets conversion resolution (see Table 3). Power-Up State = 0 Sets the thermostat fault tolerance (see Table 4). Power-Up State = 0 Sets the thermostat fault tolerance (see Table 4). Power-Up State = 0 POL = 0 -- O.S. is active low. POL = 1 -- O.S. is active high. Power-Up State = 0 TM = 0 -- Comparator mode. TM = 1 -- Interrupt mode. See the Operation--Thermostat section for a detailed description of these modes. Power-Up State = 0 SD = 0 -- Active conversion and thermostat operation. SD = 1 -- Shutdown mode. See the Shutdown Mode section for a detailed description of this mode.
TM Thermostat Operating Mode
SD Shutdown
Table 3. Resolution Configuration
R1 0 0 1 1 R0 0 1 0 1 THERMOMETER RESOLUTION (BITS) 9 10 11 12 MAX CONVERSION TIME (ms) 25 50 100 200
Table 4. Fault Tolerance Configuration
F1 0 0 1 1 F0 0 1 0 1 CONSECUTIVE OUT-OF-LIMITS CONVERSIONS TO TRIGGER O.S. 1 2 4 6
REGISTER POINTER
The four DS75LX registers each have a unique two-bit pointer designation, which is defined in Table 5. When reading from or writing to the DS75LX, the user must "point" the DS75LX to the register that is to be accessed. When reading from the DS75LX, once the pointer is set it remains pointed at the same register until it is changed. For example, if the user wants to perform consecutive reads from the temperature register, the pointer only has to be set to the temperature register one time, after which all reads will automatically be from the temperature register until the pointer value is changed. On the other hand, when writing to the DS75LX, the pointer value must be refreshed each time a write is performed, even if the same register is being written to twice in a row. At power-up, the default pointer value is the temperature register so the temperature register can be read immediately without resetting the pointer. Changes to the pointer setting are accomplished as described in the 2-Wire Serial Data Bus.
8 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Table 5. Pointer Definition
REGISTER Temperature Configuration THYST TOS P1 0 0 1 1 P0 0 1 0 1
2-WIRE SERIAL DATA BUS
The DS75LX communicates over a standard bidirectional, 2-wire serial data bus that consists of a serial clock (SCL) signal and serial data (SDA) signal. The DS75LX interfaces to the bus through the SCL input pin and opendrain SDA I/O pin. All communication is MSb first. The following terminology is used to describe 2-wire communication: Master Device: Microprocessor/microcontroller that controls the slave devices on the bus. The master device generates the SCL signal and START and STOP conditions. Slave: All devices on the bus other than the master. The DS75LX always functions as a slave. Bus Idle or Not Busy: Both SDA and SCL remain high. SDA is held high by a pullup resistor when the bus is idle, and SCL must either be forced high by the master (if the SCL output is push-pull) or pulled high by a pullup resistor (if the SCL output is open drain). Transmitter: A device (master or slave) that is sending data on the bus. Receiver: A device (master or slave) that is receiving data from the bus. START Condition: Signal generated by the master to indicate the beginning of a data transfer on the bus. The master generates a START condition by pulling SDA from high to low while SCL is high (see Figure 5). A "repeated" START is sometimes used at the end of a data transfer (instead of a STOP) to indicate that the master will perform another operation. STOP Condition: Signal generated by the master to indicate the end of a data transfer on the bus. The master generates a STOP condition by transitioning SDA from low to high while SCL is high (see Figure 5). After the STOP is issued, the master releases the bus to its idle state. Acknowledge (ACK): When a device (either master or slave) is acting as a receiver, it must generate an acknowledge (ACK) on the SDA line after receiving every byte of data. The receiving device performs an ACK by pulling the SDA line low for an entire SCL period (see Figure 5). During the ACK clock cycle, the transmitting device must release SDA. A variation on the ACK signal is the "not acknowledge" (NACK). When the master device is acting as a receiver, it uses a NACK instead of an ACK after the last data byte to indicate that it is finished receiving data. The master indicates a NACK by leaving the SDA line high during the ACK clock cycle. Slave Address: Every slave device on the bus has a unique 7-bit address that allows the master to access that device. The DS75LX's 7-bit bus address depends on the state of the external address pins A0-A2. See Table 6. The three address pins allow up to 27 DS75LXs to be multidropped on the same bus. When tying an address line high or low, connect the address line directly to VDD or GND. Do not use series resistors on these pins. Address Byte: The address byte is transmitted by the master and consists of the 7-bit slave address plus a read/write (R/W bit (see Figure 6). If the master is going to read data from the slave device then R/W = 1, and if ) the master is going to write data to the slave device then R/W = 0. Pointer Byte: The pointer byte is used by the master to tell the DS75LX which register is going to be accessed during communication. The six MSbs of the pointer byte (see Figure 7) are always 0 and the two LSbs correspond to the desired register as shown in Table 6.
9 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Figure 5. Start, Stop, and ACK Signals
SDA
... ...
START Condition ACK (or NACK) STOP From Receiver Condition
SCL
Figure 6. Address Byte
BIT 7 a6 BIT 6 a5 BIT 5 a4 BIT 4 a3 BIT 3 a2 BIT 2 a1 BIT 1 a0 BIT 0 R/W
The Address Pins A0-A2 are tri-state inputs. These can be low, high, or floating in any combination, resulting in 27 address possibilities. These map into the address byte according to Table 6.
Figure 7. Pointer Byte
BIT 7 0 BIT 6 0 BIT 5 0 BIT 4 0 BIT 3 0 BIT 2 0 BIT 1 P1 BIT 0 P0
GENERAL 2-WIRE INFORMATION
All data is transmitted MSb first over the 2-wire bus. One bit of data is transmitted on the 2-wire bus each SCL period. A pullup resistor is required on the SDA line and, when the bus is idle, both SDA and SCL must remain in a logic-high state. All bus communication must be initiated with a START condition and terminated with a STOP condition. During a START or STOP is the only time SDA is allowed to change states while SCL is high. At all other times, changes on the SDA line can only occur when SCL is low: SDA must remain stable when SCL is high. After every 8-bit (1-byte) transfer, the receiving device must answer with an ACK (or NACK), which takes one SCL period. Therefore, nine clocks are required for every 1-byte data transfer.
10 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Table 6. Address Configuration
A2 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT A1 0 0 1 1 0 FLOAT 1 FLOAT FLOAT 0 0 1 1 0 FLOAT 1 FLOAT FLOAT 0 0 1 1 0 FLOAT 1 FLOAT FLOAT A0 0 1 0 1 FLOAT 0 FLOAT 1 FLOAT 0 1 0 1 FLOAT 0 FLOAT 1 FLOAT 0 1 0 1 FLOAT 0 FLOAT 1 FLOAT ADDRESS 1001000 1001001 1001010 1001011 0101100 0101000 0101101 0101001 0110101 1001100 1001101 1001110 1001111 0101110 0101010 0101111 0101011 0110110 1110000 1110010 1110011 1110101 1110001 1110110 1110100 1110111 0110111
11 of 13
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
Writing to the DS75LX
To write to the DS75LX, the master must generate a START followed by an address byte containing the DS75LX bus address. The value of the R/W bit must be a 0, which indicates that a write is about to take place. The DS75LX responds with an ACK after receiving the address byte. This must be followed by a pointer byte from the master, which tells the DS75LX which register is being written to. The DS75LX again responds with an ACK after receiving the pointer byte. Following this ACK the master device must immediately begin transmitting data to the DS75LX. When writing to the configuration register, the master must send one byte of data (see Figure 8a), and when writing to the TOS or THYST registers the master must send two bytes of data (see Figure 8b). After receiving each data byte, the DS75LX responds with an ACK, and the transaction is finished with a STOP from the master.
Software POR
The soft POR command is hex 54. Issue a write command to the DS75LX. It responds with an ACK. If the next byte is a 0x54, the DS75LX will reset as if power had been cycled. No ACK is sent by the IC after the POR command is received.
Reading from the DS75LX
When reading from the DS75LX, if the pointer was already pointed to the desired register during a previous transaction, the read can be performed immediately without changing the pointer setting. In this case the master sends a START followed by an address byte containing the DS75LX bus address. The R/W bit must be a 1, which tells the DS75LX that a read is being performed. After the DS75LX sends an ACK in response to the address byte, the DS75LX begins transmitting the requested data on the next clock cycle. When reading from the configuration register, the DS75LX transmits one byte of data, after which the master must respond with a NACK followed by a STOP (see Figure 8c). For 2-byte reads (i.e., from the temperature, TOS, or THYST register), the DS75LX transmits two bytes of data, and the master must respond to the first data byte with an ACK and to the second byte with a NACK followed by a STOP (see Figure 8d). If only the most significant byte of data is needed, the master can issue a NACK followed by a STOP after reading the first data byte, in which case the transaction will be the same as for a read from the configuration register. If the pointer is not already pointing to the desired register, the pointer must first be updated as shown in Figure 8e, which shows a pointer update followed by a single-byte read. The value of the R/W bit in the initial address byte is a 0 ("write") since the master is going to write a pointer byte to the DS75LX. After the DS75LX responds to the address byte with an ACK, the master sends a pointer byte that corresponds to the desired register. The master must then perform a repeated START followed by a standard 1- or 2-byte read sequence (with R/W = 1) as described in the previous paragraph.
PACKAGE INFORMATION
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/DallasPackInfo.) PACKAGE 8-Pin SO 8-Pin SOP/MAX DOCUMENT NO. 56-G2008-001 21-0036
12 of 13
a) Read 2-Bytes From the Temperature, TOS or THYST Register (current pointer location) Bytes
SCL 1 0 A P LS Data Byte (from DS75LX) NACK STOP (Master) D7 D6 D5 D4 D3 D2 D1 D0 N ACK (DS75LX) MS Data Byte (from DS75LX) ACK (Master) 0 R A D7 D6 D5 D4 D3 D2 D1 D0 Address Byte 1 0 1
SDA
S
1
START
b) Write to the Configuration Register
1 0 0 W 0 P Pointer Byte ACK (DS75LX) Data Byte (from Master) ACK STOP (DS75LX) 0 0 0 0 0 1 A ACK (DS75LX) A 0 D7 D6 D5 D4 D3 D2 D1 D0 A 0 1 Address Byte
SCL
SDA S
1
1
Figure 8. 2-Wire Interface Timing
START
c) Write to the TOS or T HYST Register
1 0 0 0 ACK (DS75LX) MS Data Byte (from Master) ACK (DS75LX) Pointer Byte 0 A 1 W Address Byte A 0 0 0 0 0 P1 P0 D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A ACK (DS75LX) LS Data Byte (from Master) P ACK STOP (DS75LX)
SCL
SDA S
1
1
DS75LX: Digital Thermometer and Thermostat with Extended Addressing
13 of 13
1 0 W ACK (DS75LX) Pointer Byte 0 A 0 0 Address Byte 1 0 1 0 0 0 0 P1 P0 A S1 1 1 0 0 ACK Repeat (DS75LX ) START 1 0 R ACK (DS75LX) A 0 Address Byte 1 0 1 D7 D6 D5 D4 D3 D2 D1 D0 N Data Byte (from DS75LX) P NACK STOP (Master)
START
d) Read Single Byte (new pointer location)
1 Address Byte 0 R A D7 D6 D5 D4 D3 D2 D1 D0 N ACK (DS75LX) Data Byte (from DS75LX) P NACK STOP (Master)
SCL
SDA
S
1
START
e) Read From the Configuration Register (current pointer location) on)
SCL
SDA
S
1
START
An address byte value of 1110010 corresponds to A0 connected to VDD, A1 connected to GND, and A2 floating.